Canada starting example. Starts with a 12 m × 0.75 m Canadian Pisa quantity example, a 600 mm coping coverage, an editable 72-unit pack and a 50 ft (15.24 m) pipe coil. Enter current CAD quotes in Costs. Editable quantity assumptions; confirm the product, drainage and site design before ordering.

396 blocks · Add CAD quotesSee list ↓
Your wall
m

Measure along the wall alignment.

m

Block face only; exclude the cap.

rows

Use the embedment from your plans.

mm
mm
mm

Reference presets change block length, height and depth only. Recheck cap coverage, pallet quantity, core fill, base and drainage details against your supplier’s product and plans.

Pisa2 / RomanPisa guide: block details, printed page 5 · Canadian guide reference. Reference checked 2026-10-20. The guide lists metric and approximate imperial dimensions separately. They can produce different course rounding. Choose the reference that matches your supplier’s installed dimensions.

Cutting & breakage allowance
%
SECTION VIEW · NOT TO SCALE
0.75 mCapDrainage stoneBase aggregate1 buried courseDrainagestoneBaseaggregate1 buriedcourseWall run: 12 m
Dimensions and material zones follow your inputs. Confirm the construction detail with your wall supplier.
YOUR MATERIAL ESTIMATEPlanning quantity
396wall units to order

360 net units + 36 for cuts and breakage.

22Cap stones
4.16Stone · m³
6Whole pallets*
MaterialQuantity
Wall units300 exposed + 60 buried + 36 allowance396 blocks
Cap stones20 net + 2 allowance22 caps
Levelling base aggregateVolume plus your stone allowance1.19 m³
Drainage & core-fill stoneRectangular backfill zone plus selected core fill2.97 m³
Drain pipe1 roll(s) at 15.24 m; fittings excluded14 m
Geotextile sheet allowanceOne rear face and bottom strip, plus overlap16.56 m²
Cap adhesiveCoverage and bead count you specified7 tubes
Priced materials subtotalAdd CAD prices

CAD · 7 material line(s) unpriced. Individual units and volumes; delivery, labour and tax are extra.

See the full takeoff and prices ↓

Getting quotes? Send this list to at least 3 local installers so the quotes are comparable. How to compare quotes →

*Pallet packaging is editable. Costs use individual quantities. Material estimate only; verify products and site-specific design.

Canadian example scope: confirm local Pisa units, pack contents and coping stock-to-installed-piece conversion. Corners, reinforcement and site-specific frost/foundation details need separate verification.

Canadian starting project: Ontario Pisa units and CAD quotes

This page starts with a 12 m run and a 0.75 m exposed face using Unilock’s Ontario Pisa standard dimensions: 200 mm long, 150 mm high and 300 mm deep. The current product listing distinguishes standard, tapered and coping pieces. The estimator counts repeated uniform face units; corners, setbacks and component patterns need their own check.

One buried course, 10% unit allowance and a 72-unit pack are editable examples. The pack size comes from the Gormley standard-unit entry in Unilock’s 2022 Ontario cut sheet, not a national packaging standard. Confirm your current manufacturer, plant, colour and local bundle before purchasing. All rates start unpriced in CAD.

Worked Pisa order: 396 units and six 72-unit bundles

A 12 m course takes 60 units at 200 mm coverage. Five exposed courses plus one buried course give 360 net units. With a 10% allowance the order quantity is 396. Six complete 72-unit bundles supply 432 units, or 36 beyond the quantity allowance. If the merchant quotes per bundle, use six times its current CAD bundle quote and check split-bundle terms.

At 600 mm installed coping coverage, the run needs 20 net finished pieces and 22 with allowance. The current Ontario listing describes the 24-inch coping as a double unit. Verify how purchased stock converts to installed pieces before ordering; 22 finished coverage pieces do not necessarily mean 22 stock double units.

MaterialStarting example quantitySupplier check
Pisa standard units360 net; 396 with allowance6 × 72-unit bundles supply 432
600 mm coping coverage20 net; 22 with allowanceConfirm double-unit conversion and cuts
Base aggregate1.188 m³ including allowance600 × 150 mm example section
Drainage aggregate2.970 m³ including allowance300 mm zone; 150 mm top soil cap
Filtered perforated pipe14 m including 2 m outlet allowance1 × 50 ft coil = 15.24 m

Canadian pipe rolls, metric tonnes and delivered prices

Canadian retailers sell some drainage products in imperial package lengths. The linked Big O example is a 4-inch × 50-foot filtered perforated coil. Fifty feet equals 15.24 m exactly, so the 14 m example run fits within one coil with 1.24 m remaining. Connections, outlets and fittings are separate. Confirm the drainage specification rather than choosing pipe solely because the roll is long enough.

The combined base and drainage example is 4.158 m³ including the supply allowance. At the illustrative 1.6 t/m³ starting density that is 6.653 metric tonnes. Replace that density with the quarry’s conversion. A US short ton is about 0.907185 metric tonnes; a quote saying only “ton” needs clarification.

Request CAD prices for the actual block bundles, coping stock units, separate aggregate products, pipe, geotextile, adhesive, delivery and unloading. Confirm whether GST/HST/PST is included before using the modelled tax field. No Canadian price average or currency conversion is loaded here. Switching to US units preserves the physical project and converts the displayed price bases.

Freeze–thaw and frost: one buried course is not a depth rule

BC Housing explains that seasonal frost depth varies across British Columbia and that freezing water can heave susceptible soils. Freeze–thaw can also leave loosened subgrade. Those mechanisms help explain why soil, drainage and climate must be reviewed together; the publication is building-foundation context, not a segmental-wall approval detail.

The example’s 150 mm buried course is only a quantity assumption. It is not a Canadian frost depth and does not establish the required base or embedment. Have the selected wall supplier or designer address local frost exposure, soil susceptibility, groundwater, drainage and any permafrost conditions. The calculator cannot infer those conditions from a province name or a block count.

Calgary permit example: keep municipal and product rules separate

The City of Calgary states that a retaining wall 1.2 m or greater in height requires a development permit. Confirm the city’s measurement method and the full site conditions before relying on a height comparison. Development permission does not replace any required engineering, building, drainage or boundary review.

This is a Calgary, Alberta example. The Ontario product reference and British Columbia frost discussion above serve different purposes and do not create a single Canadian rule. Ask your own municipality about height measurement, adjacent structures, sloping ground, road or boundary proximity and the documentation required for the proposed wall.

Frequently asked questions

Why does a 50-foot coil appear as 15.24 metres?

It is the exact conversion of the retailer’s package length: 50 × 0.3048 = 15.24 m. Switching display systems keeps that same physical coil.

Is one buried 150 mm course enough for Canadian frost?

The calculator does not make that determination. One course is a counting example; local soil, frost, drainage and the selected system’s design determine the required foundation and embedment.

Do I need a permit for a retaining wall in Ontario?

Ontario requires a building permit for retaining walls that meet its designated-structure definition. For example, Building Code Division A, 1.3.3.5.(1)(a) covers walls with more than 1,000 mm (about 39.4 in) of exposed height beside public property, access to a building, or private property open to the public. Check with your municipality for the rules that apply to your site.

How deep should the base be?

Allan Block’s commercial gravity-wall detail calls for at least 150 mm (6 in) of compacted base rock in a trench at least 610 mm (24 in) wide. It also specifies at least 150 mm (6 in) of buried block and a 300 mm (12 in) drainage zone. Use the approved dimensions for your wall and site.

When does a retaining wall in Canada need a drain pipe?

Allan Block’s commercial gravity-wall detail requires a drain pipe for walls taller than 1.2 m (4 ft) or built in silty or clay soils. These are criteria for that manufacturer’s system. Follow the approved drainage detail for your project and use its pipe specification and outlet route when requesting a supplier quote.

Can I switch between metric and imperial?

Yes. The calculator starts in Metric and the US units toggle displays imperial dimensions without changing the physical project. Canadian pipe quotes can list imperial package sizes. Check whether the quote uses metres or feet and select that unit system before entering the dimensions. For aggregate, check whether the price is per tonne or per US short ton.

References and scope

Arithmetic and worked examples are explained on our methodology page. The cited sources provide product, pricing or local approval context; they do not approve a generic wall. References checked November 3, 2026.

Read the estimating and engineering limits, or send a correction.

A supplier-ready starting list

Bring your dimensions, products and assumptions together in one takeoff.

Back to the calculator